Producten

  • Elektrisk skumpumpe

    Driving a proportioning system with an electric motor is a reliable and environmentally friendly solution. Pumps with electric motors are mainly used for the InnoVdos, electronic proportioning systems and foam pump proportioners.
  • Bjælke

    InnoVfoam fremstiller bjælkemonterede systemer, hvilket betyder, at der er monteret en plug-and-play-skumblandingsbjælke i vandsluk- ningssystemet. Et sådant kundespecifikt system er fuldt testet og leveres klar til brug. Da systemet er fremstillet skræddersyet til dimensi- onerne, spildes der ikke meget tid på montering og idriftsættelse. God forberedelse garanterer effektive projektfremskridt. Vi skræddersyr systemerne helt efter kundens ønsker og designer dem specifikt til kunderne. Ofte er levering i et hus, såsom en isoleret beholder ønskeligt og undertiden fremstilles et system i dele, der skal samles på stedet i et vanskeligt tilgængeligt rum.
  • Skumkoncentratpumpe med vandturbindrev

    The proportioning system with a water driven motor does not require any external energy sources, and is reliable and environmentally friendly. Pumps with water driven motors are mainly used for the InnoVdos, electronic proportioning systems and foam pump proportioners.
  • Skumpumpe med dieselmotor

    No additional energy source is required for driving the diesel motor. The pump with diesel motor is mainly used for the InnoVdos, electronic proportioning systems and foam pump proportioners.
  • Trykskumrør

    The High Backpressure Foam Generator (HBG) is a generator intended for fixed installation. Generally used for subsurface and semisubsurface foam application in storage tanks containing flammable liquids. The generators are used with most types of foam systems like foam pumps, bladder tanks or in-line proportioners. The HBG is designed to introduce air into a water/foam-concentrate mix and is always made according to customer needs.
  • Inbal Vandkontrolventil

    The Inbal Automatic Water Control Valve series 700DX is a pressure operated, sleeve actuated, axial valve, designed from basic concepts, with a built-in actuator, to function as a control valve in fire protection systems. The Inbal series 700DX is used as deluge, preaction, dry pipe, remote control, pressure reducing, and in other types of control valves. The standard material Inbal Valve is rated to 300 psi (21 bar) and requires a minimum line pressure of 20 psi (1.5 bar) for operation. Upon removal of the control pressure, the Inbal Valve opens instantaneously, yet very smoothly, to prevent any water hammer in the piping system. The Inbal 700DX performance and ease of resetting are not affected by vertical or horizontal installation.
  • Inbal Forhandlingsventil

    The Inbal Pneumatically Actuated, Double Interlocked, Preaction Valve utilizes an Inbal Dry Pipe Valve and a pneumatic pilot system. The Inbal Valve is controlled by pressure maintained in the pneumatic release system and supervisory pressure maintained in the sprinkler piping system. The Inbal Double Interlocked Preaction Valve will open to fill the sprinkler system with water only after both of the following occurrences: Activation of the release system and relieving of supervisory pressure from the sprinkler system. As soon as the releasing system and the sprinkler piping are reset, the Inbal Double Interlocked Preaction Valve resetting is merely done by activating the reset knobs. If only the pneumatic release system operates, an alarm will activate but the Inbal Valve will not open. If the sprinkler piping is damaged or a sprinkler is broken or fused but the pneumatic release system has not activated, an alarm will activate without opening the Inbal Valve.
  • Tør alarmventilstation

    The Inbal Dry Pipe Valve is specifically designed to control the flow of water to the dry pipe sprinkler system and to provide actuation of fire alarms when the system operates. The Inbal Dry Pipe Valve is used to separate the watersupply from the dry pipe sprinkler system, by providing a bubble tight seal as long as the valve is in a set position. The Inbal Automatic Water Control  Valve which is used in this dry pipe system is a pressure operated, sleeve actuated, axial valve designed for use in fire protection systems. The trim design allows low air pressure supply to control a higher water supply pressure.
  • Trykreduktionsventil

    The Inbal Pressure Reducing Valve series 700D-01R01 is specifically designed for pressure regulating applications in fire protection systems. The Inbal 700D-01R01 Valve automatically reduces a higher inlet pressure to a preset delivery pressure, which remains steady and unaffected by the variations or fluctuations in the inlet line pressure. The series 700D-01R01 consists of the Inbal Valve which is a pressure operated, sleeve actuated, axial valve and a pressure reducing pilot control. The Inbal Pressure Reducing Valve maintains the downstream pressure within a narrow pressure range. If the downstream pressure changes slightly the pilot control responds immediately to modulate the Inbal Valve for the preset pressure.
  • Vandstationsventilstation med trykregulering

    The Inbal Pressure Control, Remote Resetting, Electrically Actuated Deluge Valve is specifically designed for use in fire protection systems which require pressure control, actuated by a remote resetting electric detection and release system. The Inbal Pressure Control, Electrically Actuated Deluge Valve, when in operation, automatically reduces a higher inlet pressure to a preset delivery pressure which remains steady and unaffected by the variations or fluctuations in the inlet line pressure.
  • Sprøjtevandventilstation

    The Remote Resetting, Electrically Actuated Inbal Deluge Valve is specifically designed for use in fire protection systems actuated by a remote resetting, electric detection and release system. The Inbal Automatic Water Control Valve used in this deluge system is a pressure operated, sleeve actuated, axial valve designed for use in fire protection systems. The Inbal Electrically Actuated Deluge Valve is used for automatic or manual operation. Electric activation of the Inbal deluge system requires a solenoid valve controlled by a control (fire alarm & releasing) panel either manually or by heat, smoke, or flame detectors. When the detection system operates, the control panel energizes the Solenoid Valve to open. When the Solenoid Valve is actuated either automatically or manually, or when a manual release station is operated locally or by remote, the Inbal Deluge Valve opens to flow water from all open sprinklers and/or nozzles on the system. After operation, the Inbal Valve can be reset by remote control, saving the need to approach the Deluge Valve for resetting.
  • Pålidelige Skumblandere

    Various types of foam proportioners for precisely proportioning foam concentrate in the water-stream of an extinguishing system can be used. The choice of proportioner depends on a number of factors: the type of extinguishing system, the required capacity, and the available energy, space (inside/outside/size) and pressure.
Go to Top