Producten

  • Inbal Deluge pressure control

    The Inbal Pressure Control, Remote Resetting, Electrically Actuated Deluge Valve is specifically designed for use in fire protection systems which require pressure control, actuated by a remote resetting electric detection and release system. The Inbal Pressure Control, Electrically Actuated Deluge Valve, when in operation, automatically reduces a higher inlet pressure to a preset delivery pressure which remains steady and unaffected by the variations or fluctuations in the inlet line pressure.
  • Inbal pressure reducing valve

    The Inbal Pressure Reducing Valve series 700D-01R01 is specifically designed for pressure regulating applications in fire protection systems. The Inbal 700D-01R01 Valve automatically reduces a higher inlet pressure to a preset delivery pressure, which remains steady and unaffected by the variations or fluctuations in the inlet line pressure. The series 700D-01R01 consists of the Inbal Valve which is a pressure operated, sleeve actuated, axial valve and a pressure reducing pilot control. The Inbal Pressure Reducing Valve maintains the downstream pressure within a narrow pressure range. If the downstream pressure changes slightly the pilot control responds immediately to modulate the Inbal Valve for the preset pressure.
  • Inbal Dry pipe valve

    The Inbal Dry Pipe Valve is specifically designed to control the flow of water to the dry pipe sprinkler system and to provide actuation of fire alarms when the system operates. The Inbal Dry Pipe Valve is used to separate the watersupply from the dry pipe sprinkler system, by providing a bubble tight seal as long as the valve is in a set position. The Inbal Automatic Water Control  Valve which is used in this dry pipe system is a pressure operated, sleeve actuated, axial valve designed for use in fire protection systems. The trim design allows low air pressure supply to control a higher water supply pressure.
  • Inbal Pre-Action valve

    The Inbal Pneumatically Actuated, Double Interlocked, Preaction Valve utilizes an Inbal Dry Pipe Valve and a pneumatic pilot system. The Inbal Valve is controlled by pressure maintained in the pneumatic release system and supervisory pressure maintained in the sprinkler piping system. The Inbal Double Interlocked Preaction Valve will open to fill the sprinkler system with water only after both of the following occurrences: Activation of the release system and relieving of supervisory pressure from the sprinkler system. As soon as the releasing system and the sprinkler piping are reset, the Inbal Double Interlocked Preaction Valve resetting is merely done by activating the reset knobs. If only the pneumatic release system operates, an alarm will activate but the Inbal Valve will not open. If the sprinkler piping is damaged or a sprinkler is broken or fused but the pneumatic release system has not activated, an alarm will activate without opening the Inbal Valve.
  • Inbal Water control valve

    The Inbal Automatic Water Control Valve series 700DX is a pressure operated, sleeve actuated, axial valve, designed from basic concepts, with a built-in actuator, to function as a control valve in fire protection systems. The Inbal series 700DX is used as deluge, preaction, dry pipe, remote control, pressure reducing, and in other types of control valves. The standard material Inbal Valve is rated to 300 psi (21 bar) and requires a minimum line pressure of 20 psi (1.5 bar) for operation. Upon removal of the control pressure, the Inbal Valve opens instantaneously, yet very smoothly, to prevent any water hammer in the piping system. The Inbal 700DX performance and ease of resetting are not affected by vertical or horizontal installation.
  • High Back Pressure Foam Generator

    The High Backpressure Foam Generator (HBG) is a generator intended for fixed installation. Generally used for subsurface and semisubsurface foam application in storage tanks containing flammable liquids. The generators are used with most types of foam systems like foam pumps, bladder tanks or in-line proportioners. The HBG is designed to introduce air into a water/foam-concentrate mix and is always made according to customer needs.
  • Foam pumps with diesel motors

    No additional energy source is required for driving the diesel motor. The pump with diesel motor is mainly used for the InnoVdos, electronic proportioning systems and foam pump proportioners.
  • Foam pumps with water driven motors

    The proportioning system with a water driven motor does not require any external energy sources, and is reliable and environmentally friendly. Pumps with water driven motors are mainly used for the InnoVdos, electronic proportioning systems and foam pump proportioners.
  • Skid-mounted system

    InnoVfoam produces skid-mounted systems, meaning that a ‘plug-and-play’ foam-proportioning skid is mounted in the water extinguishing system. A custom-made system like that is delivered fully tested and ready to use. Because the system is produced dimensionally stable, hardly any time is lost during assembly and commissioning. Proper preparation guarantees efficient project progress. We produce our systems entirely according to the client’s wishes and design everything client-specific. Clients often want the systems to be delivered in a housing such as an insulated container. In some cases, the system is produced in parts so it can be assembled on site in spaces that are difficult to reach.
  • Pumps with electric motors

    Driving a proportioning system with an electric motor is a reliable and environmentally friendly solution. Pumps with electric motors are mainly used for the InnoVdos, electronic proportioning systems and foam pump proportioners.
Go to Top